Test Code GCG Glucagon, Plasma
Additional Codes
Epic Order Name: GLUCAGON (AKA GCG)
Sunquest Order Code: GCG
Epic Px Code: LAB2254
Reporting Name
Glucagon, PUseful For
Diagnosis and follow-up of glucagonomas and other glucagon-producing tumors
Assessing diabetic patients with problematic hyper- or hypoglycemic episodes (extremely limited utility)
Performing Laboratory

Specimen Type
Plasma EDTASpecimen Required
Patient Preparation: Patient should fast for 8 hours before specimen collection.
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL
Collection Instructions:
1. Pre-chill lavender top (EDTA) tube at 4° C before drawing the specimen.
2. Draw blood into the pre-chilled tube and process as follows:
a. Chill filled tube in wet ice for 10 minutes.
b. Centrifuge in a refrigerated centrifuge or in a pre-chilled centrifuge carrier.
c. Immediately after centrifugation, aliquot plasma into a plastic vial and freeze.
Specimen Minimum Volume
0.45 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Plasma EDTA | Frozen | 90 days |
Reference Values
≥1 year of age: ≤159 pg/mL
<1 year of age: No reference interval established.
For International System of Units (SI) for Reference Values, see www.mayocliniclabs.com/order-tests/si-unit-conversion.html.
Day(s) Performed
Tuesday, Friday
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
82943
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
GLP | Glucagon, P | 2338-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
9358 | Glucagon, P | 2338-2 |
Report Available
3 to 7 daysReject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Forms
If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.