Test Code HIVUS HIV Type 1, Quantitative in Plasma using Real Time PCR
Clinical Indications
The Alinity m HIV-1 assay may be used to monitor disease prognosis by measuring the baseline plasma HIV-1 RNA level and to assess response to antiretroviral treatment by measuring changes in plasma HIV-1 RNA levels. This assay is not intended for use in screening blood, blood products, tissue or organ donors for HIV.
Additional Test Codes
Epic Order Name: HIV Viral Load PCR Quant
Sunquest Order Code: HIVUS
Epic Px Code: LAB2310
Specimen Collection Type
Pearl,Lavender
Minimum Collection Volume
2 mL Plasma
Reference Range
Not Detected
Critical Value
N/A
Interpretation
This assay has a result range of 20 to 10,000,000 copies/mL (1.30 to 7.00 log copies/mL). The limit of quantification for this RNA assay is 20 copies/mL (1.08 log copies/mL). A "Not Detected" result indicates that HIV RNA was not detected. A result of <20 copies/mL (<1.30 log copies/mL) indicates that HIV RNA is detected, but the HIV RNA level present cannot be quantified accurately below this lower limit of quantification of this assay. A numerical result is reported when HIV RNA is detected. If detected, quantitative results will be reported in copies/mL and log copies/mL.
Rejection Criteria
Specimen tube can only be associated with other PCR testing. No other testing can be performed on tube.
Specimen Availability for Add-on Testing
Test can not be added on.
Specimen Stability
Prior to centrifugation: 24 hours at 15-30oC, 48 hours at 2-8oC
After centrifugation: 24 hours at 15-30oC, 72 hours at 2-8oC
Day(s) Performed
Testing performed 3 days a week.
Performing Lab - Department
TUKHS-BH-MOLECULAR MICROBIOLOGY
Ph: 913-588-7023
CPT Code
87536
LOINC Code
70241-5
Test Alias
- HIV-1 PCR
- HIV-1 Quantitation, PCR
- Viral Load, HIV-1 RNA
- HIV-1 NAT
Additional Information / Notes
N/A