Test Code IONPF IONIZED CALCIUM, PF
Clinical Indications
N/A
Additional Test Codes
Epic Order Name: Ionized Calcium, Post Filter
Sunquest Order Code: IONPF
Px Order Code: LAB9401
Specimen Collection Type
Syringe (lithium heparin) POST Filter
Minimum Collection Volume
1 mL
Reference Range
1.0-1.3 mmol/L
Critical Value
N/A
Interpretation
N/A
Rejection Criteria
Syringe missing cap, leaks in transit, excessive air in syringe barrel, syringe or tube clotted, or specimen received after stability is exceeded.
Specimen Availability for Add-on Testing
Contact the Lab to Inquire about Add-on
Specimen Stability
2 hours from Collection
Day(s) Performed
Monday through Sunday
Performing Lab- Department
TUKHS-BH-Chemistry
CPT Code
82330
LOINC Code
50837-4
Test Alias
N/A
Additional Information / Notes
Should be ordered in conjunction with the ION for the pre-filter result