Sign in →

Test Code LATEX Latex (Hevea braziliensis) IgE (Serum)

Clinical Indications

This assay is used to detect allergen specific-IgE using the
ImmunoCAP® FEIA method. In vitro allergy testing is the primary
testing mode for allergy diagnosis.

Additional Test Codes

Epic Order Name: LATEX (HEVEA BRAZILIENSIS) IGE
Sunquest Order Code: LATEX
Epic Px Code: LAB2971

Specimen Collection Type

Preferred: Gold
Acceptable: Red

Minimum Collection Volume

0.35 mL

Reference Range

ImmunoCAP®
Quantitative Scoring Guide:

Class

IgE
(kU/L)

Comment

0

<0.10

Negative

0/1

0.10-0.34

Equivocal/Borderline

1

0.35-0.69

Low Positive

2

0.70-3.49

Moderate
Positive

3

3.50-17.49

High Positive

4

17.50-49.99

Very High
Positive

5

50.00-99.99

Very High
Positive

6

>99.99

Very High
Positive

Note that Viracor
Eurofins includes an extra calibrator at 0.10 kU/L and uses it
to
define an optional equivocal class.

Critical Value

N/A

Interpretation

The ImmunoCAP FEIA method uses as the solid phase a flexible,
hydrophobic cellulosic polymer to which allergen has been
covalently linked. The advantage of this system is that it has a
very high antigen binding capacity when compared to other systems
and it has minimal non-specific binding with high total IgE.
Viracor Eurofins provides an optional low range calibrator at 0.1
kU/L and a 0/1 class. This test has been cleared or approved for
diagnostic use by the U.S. Food and Drug Administration.

Rejection Criteria

Lipemic samples may lead to rejection

Specimen Availability for Add-on Testing

2 Days

Specimen Stability

Ambient (preferred): 4 weeks
Refrigerated: 4 weeks
Frozen: Greater than 4 weeks

Day(s) Performed

Monday through Saturday

Performing Lab- Department

TUKHS-BH-Mail Outs

CPT Code

86003

LOINC Code

N/A

Test Alias

N/A

Additional Information / Notes

Turnaround time: 1-2 business days from receipt of specimen